Challenge 01
Long spans and deflection control
Beyond about sixty metres the structure is governed by deflection, pre-camber and dynamic response, not by member strength.
How we answer it
Spans are checked for serviceability and footfall response, pre-camber is calculated and shown on the drawings, and erection-stage geometry is set so the finished shape is the designed one.